Send Message
Foshan Shunde Dongyuan Gas Appliances Industrial Co., Ltd.
TEL: 86--15015611061
Home > products > Wall Hung Gas Boiler >
LPG / NG Wall Mounted Gas Boiler 24H Timing Switch Enable Setting On / Off
  • LPG / NG Wall Mounted Gas Boiler 24H Timing Switch Enable Setting On / Off
  • LPG / NG Wall Mounted Gas Boiler 24H Timing Switch Enable Setting On / Off
  • LPG / NG Wall Mounted Gas Boiler 24H Timing Switch Enable Setting On / Off

LPG / NG Wall Mounted Gas Boiler 24H Timing Switch Enable Setting On / Off

Place of Origin SHUNDE, CHINA
Brand Name Dongyuan
Certification ISO14001,ISO9001,OHSAS18001
Model Number L1PB28-NX
Product Details
Installation:
Wall Mounted
Storage / Tankless:
Instant / Tankless
Voltage (v):
220
Gas Type:
LPG / NG
Electric Power:
110W
Lift Of Pump:
6m
Expansion Tank Capacity:
8L
Power Supply:
20-50HZ
High Light: 

wall mounted water boilers

,

wall hung condensing boiler

Payment & Shipping Terms
Minimum Order Quantity
100pcs
Price
Negotiable
Packaging Details
Each product in plastic bag which comes with the product instructions and foam packaging, then carton packaging outside with another thicker plastic bag.
Delivery Time
30days after receiving the deposit
Payment Terms
L/C, T/T, Western Union
Supply Ability
10000pcs per month
Product Description

24H timing switch enable setting on/off wall hung gas boiler with modular structure design

 

Technical data

 

Model Number L1PB24
Rated Gas Pressure(Pa) 2000/2800
Rated Gas Input(kw) 28
Rated Gas Output(kw) 24.7
Heating Area(㎡) 160-260
Gas Type NG/LPG
Electric Power(W) 130
Temp.Range Of Heating Water(℃) Radiator:30-80 Floor Heating:30-60
Efficiency Under Rated Heat Input(%) Above88%
Application Water Pressure(Mpa) 0.1-0.3
Expansion Tank Capacity(L) 8
Lift Of pump(m) 6
Power Supply 20-50HZ
Water Circulation Type Airtight Forced Circulation
The Minimum Closed Flow(L/min) 1.6
The Minimum Starting Flow (L/min) 2
△T=25℃ Hot Water Supply(kg/min) 14
△T=30℃ Hot Water Supply(kg/min) 11.7
Temp.Range Of DHW Supply(℃) 30-60
Applicative Water Pressure(mpa) 0.03-0.8
Air Input/Exhaust Duct(mm) φ60/φ100
Sparated Input/Exhaust Duct(optional) φ80/φ100
Noise On Working(DB) <42
The length Of Flue Dust(m) 1
Ignition Type Integrated Automatic Ignition
Temperature Control Gas Proportional Adjustment
Exhaust Type Forced Exhaust

 

 

- Steady ignition and work by low inlet gas pressure from 3mbar, full output by inlet gas pressure from 13mbar and higher.

- Frost protection: Burner and pump will be switch on automatically by danger of freezing. It is allowed to use antifreeze liquid instead of water in the heating system.

- All draught(open combustion chamber)and forced exhaust models.

- Can be connected with room thermostat or remote controller which providing more function options.

- Air draught model. Open chamber, especially design for house type with collective flue.

- Neat design, gas saving, high efficiency, environmental protected. Adopt advanced technology, high quality components, high efficiency combustion.

- Service menu for internal functions and working parameters adjusting.

- Frost protection: burner and pump will be switch on automatically by danger of freezing, It is allowed to use antifreeze liquid instead of water in the heating system.

- Electronic controlled fan with variable rotation speed for keeping the optimal minimal required air exceed in the gas-air mix.

- Fan burner with full gas- air premix provides gas combustion with close to ideal conditions-so the condensation process begin earlier and by higher return line temperature(about 57℃)

- Sectional stainless steel condensing heat exchanger for condensation and utilization of latent of the water vapors from exhausting smoke with efficiency till 106%.

 

 

- Digital precise temperature control system, are free to adjust temperature.

- Stable appearance,classic style, simple and handsome-one shell.

- Frost protection: burner and pump will be switch on automatically by danger of freezing. It is allowed to use antifreeze liquid instead of water in the heating system.

- Can connect with room thermostat and remote controller which can provide more function options.

- New lid design ,commissioning maintenance is very convenient.

- Digital display system pressure,more precisely.

- Main heat exchanger with high efficiency and energy-saving enable heating efficiency reach Europe Standard.

- High efficient sealed chamber system ensure sufficient burning and energy saving.

- 24H timing switch enable setting on/off with random needs.

- The main pars are come from famous brand supplier which ensure best quality.

 

 

- Unique remote control system realizing climate compensation function,ensure energy saving.

- 24H timing switch enable setting on /off with random needs.

- Integrated design of control system,120 degree turns over freely, convenience for maintenance.

- With simple operation muti-function human-machine conversation system.

- High quality copper waterway valves and pipe components ensure how water supplier reliable and comfortable.

- Multiple automatic protecting function ensure safety and reliability.

- Unique remote control system realizing climate compensation function, ensure energy safety.

-Super bigger LED display with indicate light,durable tough switch operation.( Super bigger LED display with durable touch switch operation.)

- Advanced pressure sensors technology process monitoring and water pressure displaying, ensure boiler safety.

 

 

 