Send Message
Foshan Shunde Dongyuan Gas Appliances Industrial Co., Ltd.
TEL: 86--15015611061
Home > products > Home Gas Boiler >
Hot Water Gas Central Heating Boilers , House Boiler System With LCD Display
  • Hot Water Gas Central Heating Boilers , House Boiler System With LCD Display
  • Hot Water Gas Central Heating Boilers , House Boiler System With LCD Display

Hot Water Gas Central Heating Boilers , House Boiler System With LCD Display

Place of Origin China,Shunde
Brand Name Dongyuan
Certification ISO14001,ISO9001,OHSAS18001
Model Number L1PB32-NK
Product Details
Installation:
Wall Hung
Origin:
China
Burning Style:
Radiator
Pressure:
Low Pressure
Structure:
Water Tube
Fuel:
Natural Gas
High Light: 

home heating boilers

,

residential gas boiler

Payment & Shipping Terms
Minimum Order Quantity
Negotiable
Price
Neogoitable
Packaging Details
Each product in plastic bag which comes with the product instructions and foam packaging, then carton packaging outside with another thicker plastic bag.
Delivery Time
30days after receiving the deposit
Payment Terms
L/C, T/T, Western Union
Supply Ability
10000pcs per month
Product Description

Gas Central Heating LCD Display For Room Heating And Sanitary Hot Water Home Gas Boiler

 

Technical data

 

Model Number L1PB24 L1PB32
Gas Type NG/LPG
Rated Gas Pressure(Pa) 2000/2800
Rated Gas Input(kw) 24 32
Rated Gas Output(kw) 21.1 28.2
Efficiency Under Rated Heat Input(%) Above88%
Power Supply 20-50HZ
Electric Power(W) 110 145
Temp.Range Of Heating Water(℃) Radiator:30-80 Floor Heating:30-60
Heating Area(㎡) 100-200 200-300
Lift Of pump(m) 5 7
Application Water Pressure(Mpa) 0.1-0.3
Expansion Tank Capacity(L) 6 8
Preset Pressure Of Expansion Vessel(Mpa) 0.1
Water Circulation Type Airtight Forced Circulation
△T=25℃ Hot Water Supply(kg/min) 12 16
△T=30℃ Hot Water Supply(kg/min) 10 13.3
Temp.Range Of DHW Supply(℃) 30-60
Applicative Water Pressure(mpa) 0.03-0.8
The Minimum Starting Flow (L/min) 2
The Minimum Closed Flow(L/min) 1.6
Connections(mm) For Gas&Heating Water Pipes:G3/4 For DHW Pipes:G1/2
Air Input/Exhaust Duct(mm) φ60/φ100
Sparated Input/Exhaust Duct(optional) φ80/φ100
The length Of Flue Dust(m) 1
Noise On Working(DB) <42
Exhaust Type Forced Exhaust
Ignition Type Integrated Automatic Ignition
Temperature Control Gas Proportional Adjustment
Product Dimensions(mm) 740*400*305 855*470*390
Packing Dimensions(mm) 865*470*385 870*495*390
Container(20GP/40GP/40HQ) 17//357/434 166/333/404

 

 

- With control circuit boards,control centers for high- intelligent  equipment opeartion and safety protection.

- With multi-stage intelligent antifreeze,multi-stage combustion,  the temperature is less than 8 degrees celsius 

to start automatically, the pump after sycle in th burning to stop working, the pump.

- Delay opeartion to prevent overheating repeatedly.

- With LED- all round electronic display.

- The original modular design, assembly and disassembly is simple, fault memory function, convenient for the

rapid diagnosis of after sales personnel.

- The invention patent high-frequency electronic anti scalling device and the original windbreak and sand 

structure design are committed to manufacturing gas wall hanging stove products suitable for our conditions.

- Dynamic fire display, automatic central control data output, intuitive and convenient.

 

- Touch buttons, big-screen dynamic LCD display, sensitive and comfortable.

- Digital precise temperature control system, are free to adjust temperature.

- Green environmental protection,ultra-low emission.

- Fan burner with full gas- air premix provides gas combustion with close to ideal conditions-so the condensation 

process begin earlier and by higher return line temperature(about 57℃)

- Electronic controlled fan with variable rotation speed for keeping the optimal minimal required air exceed in the

gas-air mix.

- Modulation: boiler output changes automatically to keep the set heating and DHW temperature constant, with 

great optimization of gas consumption.

- Indication of temperatures, working modes, current burner power and error codes on the color multifunctional 

LCD display.

 

 

- PCB is insensitive to the electric polarity and fluctuations of voltage AC 160-242 Volt.

- Integrated 24-hour/week timer sets normal or lower heating temperature within each day of week with the benefits 

of comfort and low gas consumption.

- Automatic electronic ignition and ionization flame control.

- Can connect with room thermostat and remote controller which can provide more function options.

- Working mode and error codes indication by 1 light- emitting diodes(LCD) on the control panel.

- Modulation: boiler output changes automatically to keep the set heating and DHW temperature constant, with great 

optimization of gas consumption.

- Frost protection: burner and pump will be switch on automatically by danger of freezing, It is allowed to use antifreeze 

liquid instead of water in the heating system.

- Supports outdoor temperature driven mode.

 

 

 

Hot Water Gas Central Heating Boilers , House Boiler System With LCD Display 0

 

 

 

 

Hot Water Gas Central Heating Boilers , House Boiler System With LCD Display 1

 

Contact Us at Any Time

86--15015611061
No.3 Depin Road, Xingtan,Shunde,Foshan,Guangdong,China
Send your inquiry directly to us